22
Installation
Prepare Appliance
The size of the existing fi replace cavity will aff ect the
method of installation. Smaller fi replaces, particularly
factory-built zero-clearance fi replaces will require the
RF24 fi rebox to be disassembled then reassembled
inside the fi replace. Plan your particular installation
accordingly.
1. Unpack appliance.
2. Unhook window cover.
3. Remove window (4 bolts).
4. Remove articles from fi rebox.
5. Strip fi rebox down by removing:
a. Log support (4 screws);
b. Burner module (4 screws);
c. Vent plate (2 screws);
d. Support Legs (2 screws per leg)
(required when inserting into
small fi replaces only)
Remove Vent Plate
(2 screws)
Remove Support Legs
(2 screws each)
Remove Burner
Module (4 screws)
Remove Log
Support (4 screws)
Remove Window (4 bolts)
Unhook Window Cover
3” dia. Aluminum Liner
Rough-in Vent Liner
Rough-in the 3” diameter vent liner into existing
chimney system being careful not to tear or damage
the liner in the process. Leave plenty of liner at the
bottom end if the heater will be connected while on the
hearth—see diagram.
When connecting the liner in this manner,
it is best to
leave the top termination until later
so the slack liner
can be lifted after the insert is in place.
Rough-In Liner
QUALIFIED
INSTALLER