18Gbps HDMI+USB-C KVM Switcher KIT
23
switch to the customized EDID .
After receiving the instruction, the
machine will prompt to send the EDID
file. The file format must be .bin within
10s (in order to ensure normal data
reception, all HDBaseT must be
disconnected before sending the
instruction)
EDID/[xx]/[yy].
The input port xx uses the built-in EDID
numbered yy.
[xx] represents the input port, the value
00-02, 00 represents all input ports, 01-
02 separately represents input 1-2;
[yy] represents the built-in EDID
number, the value is 01-12, 01-08
represents the built-in EDID that
cannot be customized, and 09-12
represents the customized EDID
Input 02 EDID Upgrade OK By
01 Internal EDID!
EDIDM[x]B[y].
The input port learns the EDID of the
output port.
[X] represents the output port number,
[X] takes the value 1-2 (or 01-02 Note:
01-02 must be used in conjunction with
00-02 below), 1-2 represents output 1-
2.1 represents output 1, 2 represents
Output 2.
[y] represents the input port, the value
is 0-2 (00-02), 0 represents all input
ports, and 1-2 separates represents
input 1-2;
Input 01 EDID Upgrade OK By
02 EXT EDID!
Baudrate[XXX].
Set control baud rate. [XXX] Support
115200, 57600, 38400, 19200, 9600
Set Local RS232 Baudrate Is
9600!
CEC[I/O][AA][BB][
CC][DD].
I/O: means input or output port, AA,
BB, CC, DD are all hexadecimal data;
AA: indicates the port number, the
CEC Input 01 Send Success!
CEC Output 01 Send Success!