Millennia Media HV-3R page 34 of 40
HV-3R
Channel
Function
Data Byte 1
Controller Number
(hex/dec)
Data Byte 2
Value
(hex/dec)
Channel 6
Pad
0x52 / 82
Off = 0x00 / 0
On = 0x7F / 127
48V
0x54 / 84
"
Polarity
0x55 / 85
"
Mute
0x57 / 87
"
Gain
0x59 / 89
See Gain Table
Channel 7
Pad
0x62 / 98
Off = 0x00 / 0
On = 0x7F / 127
48V
0x64 / 100
"
Polarity
0x65 / 101
"
Mute
0x67 / 103
"
Gain
0x69 / 105
See Gain Table
Channel 8
Pad
0x72 / 114
Off = 0x00 / 0
On = 0x7F / 127
48V
0x74 / 116
"
Polarity
0x75 / 117
"
Mute
0x77 / 119
"
Gain
0x79 / 121
See Gain Table
OMNI
Reset
HV-3R
(All
Values to
0)
0x0E / 14
Irrelevant