For more information, please visit www.devancocanada.com or call toll free at 855-931-3334
Model# CPT-210 Sensing Edge
Assembly Instructions
Components List:
CPT210-K-5
50 ft. - CPT223 extrusion
5 - Wired End Plugs
5 - Non- Terminated End Plugs or Terminated with 8.2k/10k/DC
1 - Tube Vyna Bond Glue
Step 1: Cut the Extrusion
1- Measure the width of the door.
2- Cut the extrusion 1 inch less than the door width.
Note: Ensure that the cut be square and free of rubber fragments.
Step 2: Insert the Blank End Plug and Glue.
1- Insert 50% of the blank or terminated end plug into the extrusion.
2- Apply a continuous bead of Vyna Bond glue ONLY around the perimeter.
3- Fully insert plug and hold firmly to fully seat the plug and form an
airtight seal.
4- Use caution, do not allow glue to contact conductive tongue.
Step 3: Insert the Wired End Plug and Glue.
1- Insert 50% of the wired end plug into the extrusion.
2- Apply a continuous bead of Vyna Bond ONLY around the perimeter.
3- Fully insert plug and hold firmly to fully seat the plug and form an
airtight seal.
4- Use caution, do not allow glue to contact conductive tongue.
Use Caution:
Do NOT allow glue on
the conductive tongue.
IMPORTANT:
PLEASE ENSURE THAT THE FOLLOWING INSTRUCTIONS ARE FOLLOWED
CPT TECHNOLOGY - RESISTIVE SAFETY EDGES
P.O. Box 159 • West Grove, PA 19390 • (610)869-4422 • Fax: (610)869-4423 • 800-220-3343
6809 South Harl Avenue, Suite A, Tempe, AZ 85283 • (480)755-3565 • Fax (480)755-3558 • 800-887-3343