-----------P.O. Box 159 • West Grove, PA 19390 • 800-220-3343 • 610-869-4422 • Fax: 610-869-4423 • www.milleredge.com
6809 South Harl Avenue, Suite A • Tempe, AZ 85283 • 800-887-3343 • 480-755-3565 • Fax: 480-755-3558
MEL-II-K10_Inst_20170323
Model: MEL-II-K10
INSTALLATION INSTRUCTIONS
IMPORTANT:
READ AND UNDERSTAND ALL INSTRUCTIONS BEFORE BEGINNING INSTALLATION
The Monitored Edge Link II (MEL-II) transmitter/receiver system is intended to provide a wireless connection
between a monitored safety edge and a motorized operator that controls the associated door. MEL-II meets
the UL 325 requirements for monitored devices and has been certified as a UL 325 Recognized Component. It is
designed for use on operators that comply with UL 325 using a 10K (T2) terminated sensing edge.
Please note: It may be easier to pre-
learn
the Transmitter to the Receiver prior to physically mounting the devices.
A Miller Edge 10K Sensing Edge is not needed for the
learn
process.
1.
Apply power to the receiver using a plug-in 12-24V wall transformer.
2.
Insert the two AA batteries into the Transmitter battery holder.
3.
Press
CH1 learn
button until the yellow
status
LED starts to blink rapidly (this is now
learn mode
).
4.
Within 60 seconds, press the
test
button on the Transmitter and observe on the Receiver that the
CH1
and
status
LEDs are blinking rapidly and alternately. Release Transmitter
test
button.
5.
The
CH1
red LED will continue to blink rapidly until the 10K sensing edge is connected to the Transmitter.
MEL-II-RX10
MEL-II-TX10
MEL-II-K10 COMMERCIAL DOOR INSTALLATION
Kit Contents:
MEL-II-TX10 Transmitter unit
•
MEL-II-RX10 Receiver unit
•
Receiver antenna
•
(2) AA lithium batteries
•
(4) #6 pan head Transmitter mounting screws
•
1-
Parts List
Required:
1/8” flat blade screwdriver
•
1/4” flat blade screwdriver
•
Miller Edge 10K (T2/blue band) Sensing Edge
•
Recommended:
VOM for test purposes
•
Mounting screws as required for Receiver
•