background image

-----------P.O. Box 159 • West Grove, PA 19390 • 800-220-3343 • 610-869-4422 • Fax: 610-869-4423 • www.milleredge.com

6809 South Harl Avenue, Suite A • Tempe, AZ 85283 • 800-887-3343 • 480-755-3565 • Fax: 480-755-3558

MEL-II-K10_Inst_20170323

Model: MEL-II-K10

INSTALLATION INSTRUCTIONS

IMPORTANT: 

READ AND UNDERSTAND ALL INSTRUCTIONS BEFORE BEGINNING INSTALLATION

The Monitored Edge Link II (MEL-II) transmitter/receiver system is intended to provide a wireless connection
between a monitored safety edge and a motorized operator that controls the associated door. MEL-II meets
the UL 325 requirements for monitored devices and has been certified as a UL 325 Recognized Component. It is
designed for use on operators that comply with UL 325 using a 10K (T2) terminated sensing edge.

Please note: It may be easier to pre-

learn

the Transmitter to the Receiver prior to physically mounting the devices.

A Miller Edge 10K Sensing Edge is not needed for the 

learn

process.

1.

Apply power to the receiver using a plug-in 12-24V wall transformer.

2.

Insert the two AA batteries into the Transmitter battery holder.

3.

Press 

CH1 learn

button until the yellow 

status

LED starts to blink rapidly (this is now 

learn mode

).

4.

Within 60 seconds, press the 

test

button on the Transmitter and observe on the Receiver that the 

CH1

and

status

LEDs are blinking rapidly and alternately. Release Transmitter 

test

button.

5.

The 

CH1

red LED will continue to blink rapidly until the 10K sensing edge is connected to the Transmitter.

MEL-II-RX10

MEL-II-TX10

MEL-II-K10 COMMERCIAL DOOR INSTALLATION 

Kit Contents:

MEL-II-TX10 Transmitter unit

MEL-II-RX10 Receiver unit

Receiver antenna 

(2) AA lithium batteries  

(4) #6 pan head Transmitter mounting screws

1-

Parts List

Required:

1/8” flat blade screwdriver

1/4” flat blade screwdriver

Miller Edge 10K (T2/blue band) Sensing Edge

Recommended:

VOM for test purposes

Mounting screws as required for Receiver

Reviews: