background image

www.milleredge.com        info@milleredge.com        800-220-3343        

1/5

RB-G-K10_Install_20180712

IMAGE 1. RBAND INSTALLATION WITH GATE EDGE

RBAND RECEIVER 

MOUNTED INSIDE OPERATOR  

WITH EXTERNAL ANTENNA

OPERATOR

ANTENNA

WIRING

RBAND TRANSMITTER  

MOUNTED NEAR SENSING 

EDGE

SENSING EDGE

IMPORTANT: THIS DEVICE MUST BE PROFESSIONALLY INSTALLED 

READ AND UNDERSTAND ALL INSTRUCTIONS BEFORE BEGINNING INSTALLATION

The Miller Edge RBand Monitored Gate Edge Transmitter/Receiver system is intended to provide a wireless connection between a 
monitored sensing edge and a motorized operator that controls the associated gate. The RBand Receiver is compatible with up to 3 
RBand Transmitters on 2 channels; 6 total transmitters. RBand meets the 2016 UL 325 requirements for monitored devices and has 
been certified as a UL 325 Recognized Component. It is designed for use with operators that comply with 2016 UL 325 using a Miller 
Edge 10K Sensing Edge. 

1.  PARTS LIST

RB-G-K10 Contents:
• 

RBand Gate Edge Transmitter/Receiver System:
• 

RBand Edge Transmitter (RB-TX10)

• 

RBand Gate Edge Receiver (RB-G-RX10)

• 

Receiver antenna

• 

(2) 3.6V AA lithium batteries*

• 

(4) #6 pan head transmitter mounting screws

RB-TX10 Contents:
• 

RBand Gate Edge Transmitter (RB-TX10)

• 

(2) 3.6V AA lithium batteries*

• 

(4) #6 pan head transmitter mounting screws

*Replacement 

3.6V AA lithium batteries can be purchased  

at your local electronics store or via Miller Edge.

Required:
• 

1/8” flat blade screwdriver

• 

1/4” flat blade screwdriver

• 

Miller Edge 10K (T2/blue band) Sensing Edge  

• 

Coaxial cable for exterior mounted antenna 

• 

Coaxial bulkhead adapter, female/female

Recommended:
• 

Multi-meter capable of reading 10K

Ω

• 

Mounting screws as required for receiver

2.  RECEIVER: INSTALLATION

1.  Remove the operator cover and turn off the power to the gate operator.
2.  Determine where to place the external mounted antenna so it is in line of sight with the Transmitter(s) for the entire range of 

travel [IMAGE 1]. Prepare the antenna coax as necessary. 

3.  Remove the Receiver cover and mount the base inside the operator, positioning it for optimum ease of wiring. 
4.  Connect power to the terminals marked 

12/24 AC/DC (polarity sensitive) on the removable 8-pin connector [IMAGE 2].

INSTALLATION  INSTRUCTIONS

Models: RB-G-K10, RB-TX10

Summary of Contents for Rband RB-G-K10

Page 1: ... Edge Transmitter RB TX10 RBand Gate Edge Receiver RB G RX10 Receiver antenna 2 3 6V AA lithium batteries 4 6 pan head transmitter mounting screws RB TX10 Contents RBand Gate Edge Transmitter RB TX10 2 3 6V AA lithium batteries 4 6 pan head transmitter mounting screws Replacement 3 6V AA lithium batteries can be purchased at your local electronics store or via Miller Edge Required 1 8 flat blade s...

Page 2: ...4 PIN CONNECTOR Relay Output 3 NO3 Low battery alarm optional C3 Low battery alarm optional N C Power Cycling COM COM Switched power Common A TEST 12 24VDC Switched power source TABLE 2 NORMALLY CLOSED OPERATORS Removable Connector Assignments by Manufacturer HySecurity ON 1 2 3 4 DIP Switch 4 On to run Off to test CS1 C1 BS1 CS2 C2 BS2 NO3 C3 COM ATEST 12 24 AC DC SENSOR COMMON COMMON not sensor ...

Page 3: ...s DIP SWITCH SETTINGS ON 1 2 3 4 Switch 1 3 Leave switches in factory default settings Switch 4 Used to enable Normally Closed cycle testing 10K Operator Set to off N C Operator Set to on and connect the switched power to the A Test and Common pins shown above TABLE 2 GND ANT R2 R1 R3 A TEST CHECK PROG ON 1 2 3 4 12 24 AC DC CS1 C1 BS1 CS2 C2 BS2 NO3 C3 COM ATEST MR PROGRAM BUTTON CHECK LED BUTTON...

Page 4: ...f outer covering of sensing edge cable then feed through the Transmitter strain relief fitting Connect the two sensing edge wires to the removable terminal Dress the wires with a small service loop and tighten the strain relief Mount unit utilizing the mounting holes at the 4 corners of the Transmitter box Affix lid to the Transmitter noting the alignment pin IMAGE 3 Note Altering the NEMA 4 Trans...

Page 5: ...10K termination Relay Output 3 2 Relay closes when low battery is detected A TEST 2 Connect to switched DC power and Com for N C monitoring 8 FCC COMPLIANCE RBAND EDGE TRANSMITTER Model RB TX10 FCC ID U5Z RB TX10 This device complies with Part 15 of the FCC rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 This device must accept any ...

Reviews: