OM-817 Page 4
C. Connections For Two Electrodes Same Polarity Connection (Electrode Positive Shown)
Ref. 099 082-C / Ref. 098 115-B
!
Turn off welding power
source and disconnect in-
put power before making
any input or output weld
cable connections.
1
Electrode 1
2
Electrode 2
3
A Terminal
4
Bus Bar
5
B Terminal
6
C Terminal
Tools Needed:
13/16 in.
E #2
E #1
C
B
A
( + )
FROM ELECTRODE 2
FROM ELECTRODE 1
FROM
POWER
SOURCE
S1
CONNECT WORK TO POWER SOURCE (
−
)
CONNECT BUS BAR
A TO B
1
2
3
5
6
4
D. Connections For One Electrode CV And One Electrode CC Connection (For Welding Power Source With
CV And CC Terminals)
Ref. 099 082-C / Ref. 098 115-B
!
Turn off welding power
source and disconnect in-
put power before making
any input or output weld
cable connections.
1
Electrode 1
2
Electrode 2
3
A Terminal
4
B Terminal
5
C Terminal
Tools Needed:
13/16 in.
E #2
E #1
C
B
A
MIN. IND.
MAX. IND.
FROM ELECTRODE 2
FROM ELECTRODE 1
FROM
POWER
SOURCE
S1
CONNECT WORK TO POWER SOURCE (
−
)
1
2
3
4
5