49
3.
Open the “Fast Fill” valve marked as “Valve F.”
4.
Start the product pump and run at full capacity.
5.
Slowly open the “Product Tank Fill” valve marked “Valve C” located on the front control stand.
Let run until the product tank is full, then turn OFF “Product Tank Fill” valve. There is a
breather on the product tank lid to allow air to escape during filling.
6.
Stop the product pump.
7.
Close the “Fast Fill” valve.
If Equipped With Manual Control Rinse System:
•
Turn the manual three way ball valve identified as “Valve E” (located under the platform on
left side of sprayer) to the “Product Tank” position (handle pointed toward rear of sprayer).
If Equipped With Electric Control Rinse System:
•
Located under the operator platform on the left side of the sprayer is an electric three way
ball valve. Directly behind this valve is a manual ON/OFF valve with a yellow handle.
Turn this valve ON (handle should point toward right side of sprayer). When handle is
pointed toward rear of sprayer the valve is OFF.
8.
Turn off the external water source.
9.
Remove the fill hose and replace the dust cap. Be careful when removing the fill hose from the
connector, there could still be some liquid in the line.
Valve C
Yellow
Handle
Electric 3 Way
Ball Valve
Summary of Contents for 500 BW