51
Priming The Sprayer Equipped With A RAVEN Rate Controller
If your sprayer is equipped with a RAVEN rate controller, you must do the following to allow the
spray boom to function while standing still.
1.
Disconnect the radar cable between the tractor and the sprayer.
2.
Turn RAVEN console master switch ON.
3.
Press the “Self Test” button so the red light stays on.
4.
Press “Enter” so the red light stays on.
5.
Press the No.5 key and the No. 0 key.
6.
Press “Enter” again.
Now the RAVEN rate controller is programmed with a signal telling it that it is moving, allowing the
spray boom to operate while standing still.
To Disengage Signal
1.
Reconnect the radar cable between the tractor and the sprayer.
2.
Move the tractor and sprayer or turn the rate controller OFF and then back ON.