88
Optional Accessories
In Line Filter Kit
The In Line Filter Kit is an optional accessory.
The in line filters are located on the mid section of the boom and are attached to the ON/OFF valves.
There will be one filter per ON/OFF valve and are equipped with 50 mesh screens. Optional size
screens are available through your Miller parts dealer.
WARNING
Wear protective clothing (such as goggles, rubber or chemical resistant gloves
and a respirator) while handling or working with chemicals. Keep protective
clothing clean and in good condition or discard.
To clean screens:
1.
Use caution when removing filter canisters or boom lines. There could be residual pressure in
the filter or boom lines.
2.
Place a container under the filter canister.
3.
SLOWLY loosen and remove the drain plug from the bottom of the canister and let filter drain
completely.
4.
Unscrew the filter canister, remove the screen and rinse in clean water.
5.
Wipe the inside of the canister with a clean rag.
6.
Lightly oil the o-rings on the filter canister and the drain plug.
7.
Reassemble the filter screen into the canister and the canister to the filter head. DO NOT over
tighten.
8.
Reinstall the drain plug into the canister. DO NOT over tighten.
9.
Dispose of the waste material properly.