OM-222166 Page 58
S
ROLL − Rolling Inductor
S
OPEN − no cable or plug in place
Cable 2 − This is the cable type hooked up to output number two. Possible labels:
S
AIR − for an air-cooled cable
S
LQD − for a liquid-cooled cable
S
PLUG − for a protective plug
S
OPEN − no cable or plug in place
S
ROLL − Rolling Inductor
ClntFR − This is the coolant flow rate (in GPM) from the cooler on a liquid-cooled system.
ClrSts − This is the status of the cooler. Possible labels:
S
Off
S
Flowing
The second diagnostic screen is available by again pressing and holding the Run Status
button and pressing the Parameters
Hz
V
A
kW
button.
VLnA−B: 460V Therm1: 75 DIAG2
VLnB−C: 460V Therm2: 75 Therm5: OPEN
VLnC−A: 460V Therm3: 75 ClrTmp: 77
VBus: 650V Therm4: OPEN
System Diagnostic Screen
VLnA-B − This is the phase to phase line voltage between phases A and B.
VLnB-C − This is the phase to phase line voltage between phases B and C.
VLnC-A − This is the phase to phase line voltage between phases C and A.
VBus − This is the DC bus voltage.
Therm1 − This is the temperature of the current source primary heatsink.
Therm2 − This is the temperature of the bridge heatsink.
Therm3 − This the the temperature of the current source secondary heatsink.
Therm4 − Open (not used).
Therm5 − Open (not used).
ClrTmp − This is the temperature of the coolant on a liquid-cooled system.
S
OPEN − no cooler is detected.
RmtFlw − This is the status of the relay contacts for remote coolant flow on a liquid-cooled system.
S
OFF
S
ON
.
RmtFlw feature is unsupported on the current platform.