Page 58
Accumass BW500
PL-565
Par
a
m
e
te
rs
Start Up (P001 to P017)
This is the minimum parameter programming required before attempting a calibration
and successful entry into the run mode.
P001
Language
Selects the language for communication with the BW500
entry:
1 = english
f
Note:
This manual only lists English as a choice of language. However, your BW500 will
list the additional languages of choice, as the translated software is made
available.
P002
Test Reference Selection
Selects the type of test reference used to represent a material load: weight, chain or
electronic.
weight:
the weight that is supplied specific to the scale
chain:
optional, sized specific to scale and conveyor
electronic: calibration based on automatic calculation of the mV span from the load
cells
Entry:
1 = weight
f
2 = chain
3 = ECal
P003
Number of Load Cells
Milltronics belt scales are available in models of one, two or four load cell design.
Select the number of load cells corresponding to the belt scale connected.
If using the optional remote LVDT conditioner card, for LVDT based scales, select the
“1” value.
Entry:
enter the number of load cells: 1, 2
f
or 4
P004
Rate Measurement System
Selects system of measurement used, either imperial or metric.
Entry:
1 = imperial
2 = metric
f
Summary of Contents for ACCUMASS BW500
Page 1: ...ACCUMASS BW500 Instruction Manual PL 565 January 2001 CCUMASS BW500 33455650 Rev 1 2...
Page 6: ...Page 6 Accumass BW500 PL 565...
Page 12: ...Page 12 Accumass BW500 PL 565 Specifications...
Page 28: ...Page 28 Accumass BW500 PL 565 Installation...
Page 88: ...Page 88 Accumass BW500 PL 565 Parameters...
Page 94: ...Page 94 Accumass BW500 PL 565 Operation...
Page 106: ...Page 106 Accumass BW500 PL 565 PID Control...
Page 110: ...Page 110 Accumass BW500 PL 565 Batching...
Page 112: ...Page 112 Accumass BW500 PL 565 Certification...