Page 60
Accumass BW500
PL-565
Par
am
et
e
rs
P015
Speed Constant
This value is used with the speed sensor frequency, to calculate the actual belt
speed.
(
f
=0.0000)
Entry:
If speed input is wired for constant speed (terminals 17/18 jumpered), value
defaults to '
jumpered
'.
If the speed input is connected to a speed sensor, press
. P015 automatically
jumps to P690. Refer to P690 on page 80 for speed constant entry.
P016
Belt Length
The length of the conveyor belt (one belt revolution).
(
f
=0.000)
Length units are:
feet:
if the imperial system of measurement has been selected, P004 = 1
metres:
if the metric system of measurement has been selected, P004 = 2
Enter the belt length
P017
Test Load
The load to be referenced when performing a span.
(
f
=0.00)
Load units are:
lb/ft:
if the imperial system of measurement has been selected,P004 = 1
kg/m:
if the metric system of measurement has been selected,P004 = 2
The display indicates the test reference as selected by P002; either: ‘weight’, ‘chain’
or ‘ECal’ and the multispan number MS, 1-8.
Enter the test load value
In the case of ECal, pressing enter at P017 invokes P693 for data entry. ECal sets
the value for P017 at 100% of design load (P952).
P018
Speed Adjust
This parameter allows adjustment to the speed constant (P015). Initially, this
parameter displays the dynamic speed of the belt. If the displayed speed is not equal
to the actual speed, enter the actual belt speed.
(
f
=0.00)
For speed sensor applications, the value of P015 is automatically adjusted.
For constant speed (terminals 17/18 jumpered) the value of P014 is automatically
adjusted.
Summary of Contents for ACCUMASS BW500
Page 1: ...ACCUMASS BW500 Instruction Manual PL 565 January 2001 CCUMASS BW500 33455650 Rev 1 2...
Page 6: ...Page 6 Accumass BW500 PL 565...
Page 12: ...Page 12 Accumass BW500 PL 565 Specifications...
Page 28: ...Page 28 Accumass BW500 PL 565 Installation...
Page 88: ...Page 88 Accumass BW500 PL 565 Parameters...
Page 94: ...Page 94 Accumass BW500 PL 565 Operation...
Page 106: ...Page 106 Accumass BW500 PL 565 PID Control...
Page 110: ...Page 110 Accumass BW500 PL 565 Batching...
Page 112: ...Page 112 Accumass BW500 PL 565 Certification...