Page 4
ILE-61 Sensing Head – INSTRUCTION MANUAL
7ML19981CX01
Sensor Type
•
LVDT (linear variable differential transformer)
LVDT Excitation:
•
2.50 Vac @ 2.9 kHz (supplied by Flowmeter Integrator or LVDT Conditioner Card)
LVDT Output:
•
0 - 0.75 Vac @ 2.9 kHz
Damping Fluid:
•
10 - 100 cm
2
/s (1000 - 10 000 cs) silicone, (Dow Corning 200)
Options:
•
Epoxy, Teflon
1
,® or Tufram
2
® frame coating
•
Epoxy painted mild steel or stainless steel rear cover
•
CSA Class I - groups C & D, Class 2 - groups E, F, & G
Approvals
•
CE
SENSING PLATE
Construction:
•
304 stainless steel
Options:
•
316 stainless steel 6
•
UHMW polyurethane or Ceramic Tile lining
•
Teflon®or plasma coating
LVDT Conditioner Card
Power
•
± 5 Vdc (typically from an Accumass integrator)
1.
Tufram®is a registered trademark of General Magnaplate.
2.
Teflon®is a registered trademark of DuPont.