7ML19981CX01
ILE-61 Sensing Head – INSTRUCTION MANUAL
Page 5
Ambient Temperature
•
-20 to 50°C (-2 to 122°F)
Input
•
0 to 1.0 V from LVDT
Output
•
0 to 50 mV to Accumass SF500 (maximum 300 m (1000 ft) separation between
Conditioner Card and integrator)
Approvals
•
CE
Enclosure
•
NEMA 4 (remote mounted unit)
Cable
For connection between LVDT Conditioner Card and Integrator
•
Belden 8404, 4 conductor, shielded 20 AWG or equivalent, 150 m (500 ft) maximum
•
Belden 9260, 6 conductor, shielded 20 AWG or equivalent, 300 m (1000 ft) maximum
For connection between LVDT and remote LVDT Conditioner Card,
or directly between LVDT and Integrator
•
Belden 8404, 4 conductor, shielded 20 AWG or equivalent, 300 m (1000 ft) maximum