60
T
T
T
L
L
L
1
1
1
4
4
4
/
/
/
4
4
4
0
0
0
T
T
T
L
L
L
1
1
1
5
5
5
/
/
/
4
4
4
0
0
0
Rapid Traverse
300 ipm
7.6 mpm
300 ipm
7.6 mpm
Feedrate Range
.1-100 ipm
2.5 - 2540 mmpm
.1-100 ipm
2.5 - 2540 mmpm
Position Accuracy
See note
±.0004"
.010 mm
±.0004"
.010 mm
Repeatability
See note
.0004"
.001 mm
.0003"
.0076 mm
Resolution .0001"
.001 mm
.0001"
.001 mm
Thrust, Machine Duty Rating
X: 800 lbs.
360 kg
Z: 1600 lbs.
725 kg
X: 1000 lbs
450 kg
Z: 2000 lbs
900 kg
CENTURION 7 CNC
Control, PC Based
Standard
Standard
LCD Color Display
Standard
Standard
Keys & Buttons, Tactile
Standard
Standard
Upgrade to Discrete Key Front Panel
Optional Optional
Conversational & G/M Code with Full Graphics
Standard Standard
Turning, Facing, Grooving, Tapping and Boring Cycles, and
User-definable Macros with Trig Help
Package A
Package A
Constant Surface (RPM changes with radius) and Feed/Rev.
(IPR) with Threading Cycles
Package A
Package A
Pattern Repeat, Chamfering, Radius Prog. Assist with Handwheel
Teach Mode
Package A
Package A
Dual Handwheel Station for Selecting Teach, Manual or Automatic
Operation
Package B
Package B
2 Mb Parts Storage Memory
Standard
Standard
Additional 8 Mb Parts Storage Memory
Package A
Package A
6 Mb Virtual Disk / DNC buffer
Standard
Standard
8 Mb Program Execution Memory
Package A
Package A
Additional 16 Mb Program Execution Memory
Package C
Package C
Networking
Package C
Package C
256 Mb Memory Capacity
Package C
Package C
3 ½" Floppy Drive
Package A
Package A
MISCELLANEOUS
Automatic Home Sequence, Chuck Guards, Safety Switch
Standard Standard
5C Royal Collet Closer with Foot Switch
Optional
Optional
Work Lamp
Package B
Package B
Full Enclosure with Sliding Doors and Safety Switch
Standard
Standard
Auto Metered Lubrication with Low Lube Fault
Standard
Standard
1/8 Horsepower Flood Pump Option
Package B
Package B
Flood Coolant Capacity
25 gal.
90 L
25
gal.
90 L
Way Surface
Hardened/Ground
Hardened/Ground
Power Requirements 208-240 VAC, 50 – 60 hz, 3Ø
30 amps 11 kVA
30 amps 11 kVA
Power 208-240 VAC, Single Phase
Optional
Optional
Power 380-480 VAC, 50 – 60 hz, 3Ø
Req Transformer
Req Transformer
Warranty
Parts: 2 Years (or 4200 hours, whichever occurs first) on all normal failures.
Service: 1 Year (or 2100 hours, whichever occurs first) from dealer or
available from factory for second 6 months if air ticket supplied.
Floor Space Requirement
60" x 104"
1524 x 2640 mm
74" x 109"
1875 x 2760 mm
Notes: Measurements performed with Renishaw laser. Measurements are linear over entire travel, and
temperature changes and loading may affect tolerances. Centurion features covered under separate
literature. Additional Centurion 7 features and additional options covered under separate literature.
Milltronics reserves the right to change specifications at any time without incurring obligation.
Summary of Contents for ML Series
Page 2: ......
Page 4: ......
Page 6: ......
Page 20: ......
Page 23: ...CHAPTER 2 SPECIFICATION ML14 26 Series Machine Layout 17 ...
Page 24: ...ML35 40 Series Machine Layouts ML35 Series ML40 Series 18 ...
Page 33: ...CHAPTER 3 SITE PREPARATION 27 ML22 ML26 Lifting device drawing ...
Page 34: ......
Page 74: ......
Page 76: ......
Page 78: ......
Page 80: ......
Page 82: ......
Page 83: ......