Chapter 3. Routine Maintenance
PELLERIN MILNOR CORPORATION
Table 3: Filters, Screens, and Sensitive Components
Remove contamination from these components to prevent damage and unsatisfactory performance.
Mark
1
2
3
4
5
6
Do this each
Component
x
40 to 60 hours
inverter fans, vents, filters
See
. Keep good air flow.
x
600 hours
motors
Keep good air flow.
x
2400 hours
entire machine
Remove excessive dust and dirt.
x
day*
chemical inlet areas
Some chemical supplies that stay on machine
surfaces will cause corrosion damage. See
Damage From Chemical Supplies and
Chemical Systems”
x
day*
self-purging filter (and
regulator) for compressed air
See
automatically.
x
200 hours
filter element for the filter
(and reguator)
Replace the filter if you cannot remove
contamination.
x
2400 hours
strainer in water regulator for
optional supply injector and
pumped chemicals on some
models.
See
x
200 hours
strainer(s) for air inlet
See
x
200 hours
strainer for steam inlet.
(Steam is optional on some
models.)
See
x
200 hours
speed sensor (photoeye)
See
x
2400 hours
proximity switches
See
x
1200 hours
oil filter for hydraulic tank
See
. Replace the used with a new
one. Speak to your dealer or Milnor.
24
Summary of Contents for 48040F7B
Page 2: ......
Page 4: ......
Page 5: ...English 1 1 ...
Page 6: ......
Page 8: ...Applicable Milnor products by model number 48040H7N 68036H5N 4 ...
Page 51: ...Deutsch 2 47 ...
Page 52: ......
Page 54: ...Gilt für die Milnor Produkte mit den folgenden Modellnummern 48040H7N 68036H5N 50 ...
Page 99: ...中国的 3 95 ...
Page 100: ......