background image

Published Manual Number/ECN: H000000044/2000493N

•  Publishing System: TPAS
•  Access date: 1/30/01
•  Document ECN's: Latest Available

Kit Instruction—

KWACSD001R

PELLERIN MILNOR CORPORATION

POST OFFICE BOX 400, KENNER, LOUISIANA 70063-0400, U.S.A.

Summary of Contents for KWACSD001R

Page 1: ...l Number ECN H000000044 2000493N Publishing System TPAS Access date 1 30 01 Document ECN s Latest Available Kit Instruction KWACSD001R PELLERIN MILNOR CORPORATION POST OFFICE BOX 400 KENNER LOUISIANA 70063 0400 U S A ...

Page 2: ...ublishing system access date and whether the document ECN s are the latest available or exact References to Yellow Troubleshooting Pages This manual may contain references to yellow pages Although the pages containing troubleshooting procedures are no longer printed on yellow paper troubleshooting instructions if any will be contained in the easily located Troubleshooting chapter or section See th...

Page 3: ......

Page 4: ......

Page 5: ...r spray and reset the sprinkler Permit the water to drain from the basket housing and base Ê Checking for Obvious Damage SHOCK HAZARD Electrical power can cause death or severe injury Lock OFF and tag out power to the machine main bus at the wall disconnect before check ing for obvious damage Power switches on control panel disable only control circuit power in certain electrical boxes Inspect the...

Page 6: ...o MAN UAL to fully open the unload door and enable the Jog switch 2 Hold the Jog switch CW or CCW as needed to re move goods then return the Manual Auto matic switch to AUTOMATIC Ê Checking for Hidden Damage With the machine in Manual check for hidden damage by operating all controls e g Modulating Gas valve stripper etc See ACTUATING OUTPUTS VIEWING INPUTS AND ACCESSING DATA ACCUMULA TION ON THE ...

Page 7: ...NG FOR LOAD Enables the sprinkler funtion 1 RELEASE VALVE Commands sprinkler ON operator signal beacon illuminates alarm sounds and sprinkler reset handle pops up verifying valve open Momentarily turn ON water valve and confirm that water flows from the sprinkler openings to the basket housing 1 RELEASE VALVE Returns to TEST SPRINKLER MENU Pull down sprinkler reset handle until it resets NOTE Oper...

Page 8: ...s WAITING FOR LOAD Accesses Manual Load menu SELECT DRYCODE 00 REDRY Ë For Quick Return to Run Mode from SPRINKLER TEST etc returns to automatic WAITING FOR LOAD Accepts the default Drycode 00 and prompts for load size if machine configured for more than one cake ENTER LOAD SIZE 0 FULL LOAD Accepts the default load size full load and prompts the operator to load dryer Ignore this prompt LOAD DRYER...

Page 9: ...sprinkler openings in basket Reset the sprinkler reset handle to reset the system Turn ON water valve Clears the three wire disable error Display shows ROTATIONAL FAILURE Clears the rotational failure error Display shows CHECK ERROR LIGHTS Clears the check error lights message The machine resumes current dry code 00F TIF TOF 000 VP XX XXXAXXX XXX XXX alternates with 00F TIF TOF 021 AIR XXX XXXDXXX...