Too Long to Drain
— The controller issues an error but the drain remains open. If a slow drain
caused the error, the error clears and the formula resumes when the transducer senses that the
water level has dropped to the desired level.
Drain Blocked:
The drain pipe from the machine to the sewer may be blocked. Check the drain
pipe and remove any obstruction.
Transducer Tube Blocked:
The tube from the shell to the pressure transducer (
) may
be blocked. Check the tube and remove lint or other obstructions.
Drain Valve Malfunctioned:
The drain valve or drain valve solenoid may have malfunctioned.
Electrical troubleshooting is required (see
).
Figure 26.
Transducer Tube
Figure 27.
Schematic of Typical Drain Circuit
Serial Communication Failure
— A peripheral board in the control box has lost communica-
tion with the processor board. The controller stops cylinder rotation and waits for serial commu-
nication to resume. This error dialog box closes when serial communication resumes.
Board Failure:
A peripheral board in the control box cannot communicate with the pro-
cessor board. Electrical troubleshooting is required.