Pellerin Milnor Corporation
Prevent Damage from Chemical Supplies and
Chemical Systems
BNUUUR02.C01 0000160549 D.2 B.2 7/19/19 10:22 AM Released
All Milnor
®
washer-extractors and CBW
®
tunnel washers use stainless steel with the ANSI 304
specification. This material gives good performance when chemical supplies are correctly ap-
plied. If chemical supplies are incorrectly applied, this material can be damaged. The damage can
be very bad and it can occur quickly.
Chemical supply companies usually:
•
supply chemical pump systems that put the supplies in the machine,
•
connect the chemical pump system to the machine,
•
write wash formulas that control the chemical concentrations.
The company that does these procedures must make sure that these procedures do not cause dam-
age.
Pellerin Milnor Corporation accepts no responsibility for chemical damage to the ma-
chines it makes or to the goods in a machine.
1.
How Chemical Supplies Can Cause Damage
BNUUUR02.R01 0000160548 D.2 B.3 11/27/18 2:24 PM Released
Dangerous Chemical Supplies and Wash Formulas
— Some examples that
can cause damage are:
•
a very high concentration of chlorine bleach,
•
a mixture of acid sour and hypo chlorite,
•
chemical supplies (examples: chlorine bleach, hydrofluosilicic acid) that stay on the stainless
steel because they are not quickly flushed with water.
The book “Textile Laundering Technology” by Charles L. Riggs gives data about correct chemi-
cal supplies and formulas.
Incorrect Configuration or Connection of Equipment
— Many chemical
systems:
•
do not prevent a vacuum in the chemical tube (for example, with a vacuum breaker) when the
pump is off,
•
do not prevent flow (for example, with a valve) where the chemical tube goes in the machine.
Damage will occur if a chemical supply can go in the machine when the chemical system is off.
Some configurations of components can let the chemical supplies go in the machine by a siphon
(
Figure 1: Incorrect Configurations That Let the Chemical Supply Go In the Machine by a Si-
). Some can let chemical supplies go in the machine by gravity (
Configurations That Let the Chemical Supply Go In the Machine by Gravity, page 3
I
BIWUUI03 / 2019296
BNUUUR02
0000160550
D.2
8/14/19 2:05 PM
Released
22
Summary of Contents for MilTouch MWF27Z8 Series
Page 2: ......
Page 23: ...Installation 1 19 ...
Page 39: ...Service and Maintenence 2 35 ...
Page 61: ...Drive Assemblies 3 57 ...
Page 72: ......
Page 73: ...Suspension 4 69 ...
Page 78: ......
Page 79: ...Shell and Door Assemblies 5 75 ...
Page 89: ...Water and Steam Piping and Assemblies 6 85 ...
Page 96: ......
Page 97: ...Chemical Supply Devices 7 93 ...
Page 107: ...Dimensional Drawings 8 103 ...
Page 108: ......
Page 109: ...105 ...
Page 110: ...106 ...