Close the line.
— If the pump does not always close the line when it is off, use a shutoff
valve to do this.
Do not let a vacuum occur.
— Supply a vacuum breaker in the chemical line that is
higher than the full level of the tank.
Flush the chemical tube with water.
— If the liquid that stays in the tube between
the pump and the machine can flow in the machine, flush the tube with water after the pump
stops.
Put the chemical tube fully below the inlet.
— It is also necessary that there is no
pressure in the chemical tube or tank when the system is off.
Figure 4. A Configuration that Prevents Flow in the Machine When the Pump is Off (if the chemical
tube and tank have no pressure)
Schematic View
Legend
I...
Chemical inlet on the machine
L...
Chemical tube
P...
Pump
T...
Chemical tank
Prevent leaks.
— When you do maintenance on the chemical pump system:
•
Use the correct components.
•
Make sure that all connections are the correct fit.
•
Make sure that all connections are tight.
End of document: BNUUUR02
Prevent Damage from Chemical Supplies and Chemical Systems
26
Summary of Contents for MilTouch MWF27Z8 Series
Page 2: ......
Page 23: ...Installation 1 19 ...
Page 39: ...Service and Maintenence 2 35 ...
Page 61: ...Drive Assemblies 3 57 ...
Page 72: ......
Page 73: ...Suspension 4 69 ...
Page 78: ......
Page 79: ...Shell and Door Assemblies 5 75 ...
Page 89: ...Water and Steam Piping and Assemblies 6 85 ...
Page 96: ......
Page 97: ...Chemical Supply Devices 7 93 ...
Page 107: ...Dimensional Drawings 8 103 ...
Page 108: ......
Page 109: ...105 ...
Page 110: ...106 ...