Chapter 1. How to Use the MilTouch Control
PELLERIN MILNOR CORPORATION
for how you will use it, temperature and water units, etc.
1.1.1.2.
1.1.
Type
—Select the type of machine shown on the machine name plate. The name plate is on the
back side of the machine.
1.1.1.2.
1.2.
Name
—Set a machine name to describe the machine on printed reports.
1.1.1.2.
1.3.
Laundry Type
—Set the type of goods this machine will process most often. This selection sets
the 10 default formulas available without programming. This version of the machine software
provides default formulas for the commercial configuration.
1.1.1.2.
1.4.
Language
—Set a language for the machine prompts. The only current choice is English.
1.1.1.2.
1.5.
Water Unit
—Set whether bath height will be displayed and programmed in inches or
centimeters.
1.1.1.2.
1.6.
Water Offset
—Set a digital counts value here so the displayed bath level on the
Run
screen is
the same as the actual bath level in the machine.
1.1.1.2.
1.7.
Water Levels
—Set a value for each water level. Water Level 1 must be the lowest level, and
Water Level 6 must be the highest.
1.1.1.2.
1.8.
Temperature Probe
—Set whether this machine has a temperature sensor. A temperature
sensor allows programming a specific temperature for each bath step.
1.1.1.2.
1.9.
Temperature Unit
—Set whether bath temperature will be displayed and programmed in
degrees Fahrenheit or degrees Celsius.
1.1.1.2.
1.10.
Steam Error
—Set the time allowed for the machine to use steam to achieve the programmed
bath temperature.
1.1.1.2.
1.11.
Cooldown Error
—Set the time allowed for the machine to complete a cooldown to a
programmed bath temperature.
1.1.1.2.
1.12.
Extra Water
—Set whether this machine is attached to a third water source.
1.1.1.2.
1.13.
Reuse Drain
—Set whether this machine has a reuse tank and a second drain valve.
1.1.1.2.
1.14.
RinSave
—Set whether to allow RinSave steps in wash formulas.
1.1.1.2.
1.15.
Fill Error
—Set the maximum time allowed for the machine to fill to the desired level.
1.1.1.2.
1.16.
Counts per 10 RPMs
—Set the number of counts from the digital-to-analog board required to
change the basket speed by 10 RPMs. Do not make a change to this value before you consult with
the Milnor factory.
1.1.1.2.
1.17.
Password Menu button
—Set a password to restrict access to programming, configuration,
and manual functions. Also, set the date and time for the machine.
13
Summary of Contents for MilTouch
Page 2: ......
Page 4: ......
Page 5: ...English 1 1 ...
Page 6: ......
Page 47: ...中国的 2 43 ...
Page 48: ......
Page 87: ...Français 3 83 ...
Page 88: ......
Page 134: ......
Page 135: ...Deutsch 4 131 ...
Page 136: ......