background image

3

Fig.3

Fig.4

Fig.5

Fig.2

Downrod Installation

Fig.6

Safety Cable

“J” Hook

Screw

Ceiling

Safety Cable

Bolt

Nut

Cotter pin

Spring Washer

Ceiling

Hook

Pulley

a

3

“U” Hook mounted

Remove the bolt, stop pin, 

nut, washer and rubber pulley from the downrod. 

(Fig.4)

4

Place the pulley onto the Hook.(Fig.a) 

5

Lift the motor until the bracket hole of the 

downrod 

aligning the pulley hole.Tighten the 

downrod to the pulley with the previous bolt

washer

nut and contter pin.

Pulley

Bolt

Downrod

Nut

Cotter pin

Spring Washer

Bolt

Nut

Cotter pin

Spring Washer

Flat Washer

Bolt

Lead wire

Safety cable

Grounding wire

6

“U” Hook mounted, Lift the fan onto the

mounted hook,until the hanging wheel seat on

the mounted J hook 

.(Fig.6) 

Summary of Contents for MCF- E120

Page 1: ...or installing reference only Model MILUX SALES SERVICE SDN BHD Head Office No 31 Lorong Jala 14 KS10 Off Jalan Telok Gong 42000 Port Klang Selangor Malaysia Tel 603 31341254 Fax 603 31341193 Toll Free...

Page 2: ...connection are tightly screwed and secured 10 An all pole disconnection must be incorporated in the fixed wiring in accordance with the wiring rules a all pole disconnection incorporated in the fixed...

Page 3: ...er pin Fig 3 2 Downrod Installation a b c d e 1 2 3 4 5 6 7 1 2 3 4 5 6 7 Qty Parts 1 1 Downrod 2 1 Ceiling canopy 3 1 Yoke cover 4 1 Fan motor assembly 5 3 Fan blade 6 1 Bottom cover 7 1 set Balance...

Page 4: ...4 Place the pulley onto the Hook Fig a 5 Lift the motor until the bracket hole of the downrod aligning the pulley hole Tighten the downrod to the pulley with the previous bolt washer nut and contter p...

Page 5: ...d Safety Cable must be fixed correctly May cause injury if ceiling fan drops Screw Screw Safety Cable 1 2 3 Install Safety Cable Blades Installation Blade Blade screws Flat washer 1 Insert the blade s...

Page 6: ...ckwise Fig 9 1 Remove the 4 light kit screws from switch housing 2 Connect the quick connector and then put them into the switch housing 3 Attached the light kit to switch housing and align the screw...

Page 7: ...ieces of lead wires from the screws bag and connect the wire to the fan Fig 11 4 Connect the fan wire to the house s supply wire Diagram shows a complete assembly of the ceiling fan Fig 12 Fig 13 5 Fi...

Page 8: ...light coat of shoe polish over it 5 There is no need to lubricate the fan Troubleshooting Check on the following before lodging a service report SYMPTOM PROBLEM SOLUTION Fan not moving 1 Main cables...

Page 9: ...rt a fault please contact our customer service center at MILUX SALES SERVICE SDN BHD 302263 X No 31 Lorong Jala 14 KS10 Off Jalan Telok Gong 42000 Port Klang Selangor Malaysia Tel 603 31341254 Toll Fr...