16
17
SB2-35 D
B2E 16 RLD
........................... 1010 W ................................ 900 W
............................. 505 W ................................ 450 W
............................. 800 /min ............................ 750 /min
........................... 1800 /min .......................... 1600 /min
............................. 650 /min ............................ 450 /min
........................... 1350 /min .......................... 1000 /min
........................... 1600 /min .................................-
............................... 35 mm ..................................-
............................... 40 mm ..................................-
............................... 16 mm ............................... 16 mm
............................... 20 mm ............................... 20 mm
............................... 50 mm ............................... 40 mm
............................3-16 mm ............................3-16 mm
..................... M18x2,5 ........................... M18x2,5
............................... 57 mm ............................... 57 mm
.............................. 4,2 kg ................................ 4,2 kg
............................... 10 m/s
2
.............................. 10 m/s
2
............................. 100 dB (A) ........................... 86 dB (A)
..............................111 dB (A) ........................... 97 dB (A)
SB2-35 D
B2E 16 RLD
........................... 1010 W ................................ 900 W
............................. 505 W ................................ 450 W
............................. 800 /min ............................ 750 /min
........................... 1800 /min .......................... 1600 /min
............................. 650 /min ............................ 450 /min
........................... 1350 /min .......................... 1000 /min
........................... 1600 /min .................................-
............................... 35 mm ..................................-
............................... 40 mm ..................................-
............................... 16 mm ............................... 16 mm
............................... 20 mm ............................... 20 mm
............................... 50 mm ............................... 40 mm
............................3-16 mm ............................3-16 mm
..................... M18x2,5 ........................... M18x2,5
............................... 57 mm ............................... 57 mm
.............................. 4,2 kg ................................ 4,2 kg
............................... 10 m/s
2
.............................. 10 m/s
2
............................. 100 dB (A) ........................... 86 dB (A)
..............................111 dB (A) ........................... 97 dB (A)
ENGLISH
TECHNICAL DATA
Rated input
..............................................................................................
Output ......................................................................................................
No-load speed, 1st gear
..........................................................................
No-load speed, 2nd gear
.........................................................................
Speed under load max., 1st gear
............................................................
Speed under load max., 2nd gear
...........................................................
Rate of percussion under load max.
........................................................
Drilling capacity in concrete
.....................................................................
Drilling capacity in brick and tile
..............................................................
Drilling capacity in steel
...........................................................................
Drilling capacity in Aluminium
..................................................................
Drilling capacity in wood
..........................................................................
Drill opening range ..................................................................................
Drive shank..............................................................................................
Chuck neck diameter
...............................................................................
Weight according EPTA-Procedure 01/2003
...........................................
Typical weighted acceleration in the hand-arm area
...............................
Typical A-weighted sound levels:
Sound pressure level (K = 3 dB(A))
.......................................................
Sound power level (K = 3 dB(A))
...........................................................
Measured values determined according to EN 60 745.
SAFETY INSTRUCTIONS
Please pay attention to the safety instructions in the attached lealet!
Wear ear protectors.
Exposure to noise can cause hearing loss.
Use auxiliary handles supplied with the tool.
Loss of control can
cause personal injury.Appliances used at many different locations
including open air must be connected via a current surge preventing
switch.
Appliances used at many different locations including open air must be
connected via a current surge preventing switch.
Always wear goggles when using the machine. It is recommended to
wear gloves, sturdy non slipping shoes and apron.
Sawdust and splinters must not be removed while the machine is
running.
Always disconnect the plug from the socket before carrying out any
work on the machine.
Only plug-in when machine is switched off.
Keep mains lead clear from working range of the machine. Always
lead the cable away behind you.
When working with large drill diameters, the auxiliary handle must be
fastened in a right angle with the main handle (see illustrations,
section „Twisting the handle“).
Do not use diamond core drills on hammer mode.
When working in walls ceiling, or loor, take care to avoid electric
cables and gas or waterpipes.
SPECIFIED CONDITIONS OF USE
The percussion drill can be universally used for drilling and percussion
drilling.
Do not use this product in any other way as stated for normal use.
MAINS CONNECTION
Connect only to single-phase a.c. current and only to the system
voltage indicated on the rating plate. It is also possible to connect to
sockets without an earthing contact as the design conforms to safety
class
II
.
EC-DECLARATION OF CONFORMITY
We declare under our sole responsibility that this product is in
conformity with the following standards or standardized documents.
EN 60745-1:2009 + A11:2010
EN 60745-2-1:2010
EN 55014-1:2006 + A1:2009 + A2:2011
EN 55014-2:1997 + A1:2001 + A2:2008
EN 61000-3-2:2006 + A1:2009 + A2:2009
EN 61000-3-3:2008
in accordance with the regulations
2011/65/EU (RoHs)
2006/42/EC
2004/108/EC
Winnenden, 2012-09-12
Rainer Kumpf
Director Product Development
Authorized to compile the technical ile
MAINTENANCE
The ventilation slots of the machine must be kept clear at all times.
Use only Milwaukee accessories and Milwaukee spare parts. Should
components need to be replaced which have not been described,
please contact one of our Milwaukee service agents (see our list of
guarantee/service addresses).
If needed, an exploded view of the tool can be ordered. Please state
the ten-digit No. as well as the machine type printed on the label and
order the drawing at your local service agents or directly at:
Milwaukee
Electric Tool, Max-Eyth-Straße 10, D-71364 Winnenden, Germany
.
SYMBOLS
Always disconnect the plug from the socket before
carrying out any work on the machine.
Accessory - Not included in standard equipment,
available as an accessory.
Do not dispose of electric tools together with
household waste material! In observance of
European Directive 2002/96/EC on waste electrical
and electronic equipment and its implementation in
accordance with national law, electric tools that have
reached the end of their life must be collected
separately and returned to an environmentally
compatible recycling facility.
Class II construction, tool in which protection
against electric shock does not rely on basic
insulation only, but in which additional safety
precautions, such as double insulation or
reinforced insulation, are provided.
The data stated above apply for models with 230 - 240 V. In case of deviating mains voltage, the data stated on the rating plate are applicable.
DEUTSCH
TECHNISCHE DATEN
Nennaufnahmeleistung
............................................................................
Abgabeleistung ........................................................................................
Leerlaufdrehzahl im 1. Gang
...................................................................
Leerlaufdrehzahl im 2. Gang
...................................................................
Lastdrehzahl max. im 1. Gang
.................................................................
Lastdrehzahl max. im 2. Gang
.................................................................
Lastschlagzahl max.
................................................................................
Bohr-ø in Beton .......................................................................................
Bohr-ø in Ziegel und Kalksandstein
.........................................................
Bohr-ø in Stahl.........................................................................................
Bohr-ø in Aluminium
................................................................................
Bohr-ø in Weichholz
................................................................................
Bohrfutterspannbereich
...........................................................................
Bohrspindel
..............................................................................................
Spannhals-ø ............................................................................................
Gewicht nach EPTA-Prozedur 01/2003
...................................................
Typisch bewertete Beschleunigung im Hand-Arm-Bereich
.....................
Typische A-bewertete Schallpegel:
Schalldruckpegel (K = 3 dB(A))
.............................................................
Schalleistungspegel
(K = 3 dB(A))
.........................................................
Messwerte ermittelt entsprechend EN 60 745.
SPEZIELLE SICHERHEITSHINWEISE
Sicherheitshinweise der beiliegenden Broschüre beachten!
Tragen Sie Gehörschutz.
Die Einwirkung von Lärm kann
Gehörverlust bewirken.
Benutzen Sie die mit dem Gerät gelieferten Zusatzhandgriffe.
Der
Verlust der Kontrolle kann zu Verletzungen führen.
Steckdosen in Außenbereichen müssen mit Fehlerstrom-
Schutzschaltern ausgerüstet sein. Das verlangt die
Installationsvorschrift für Ihre Elektroanlage. Bitte beachten Sie das
bei der Verwendung unseres Gerätes.
Beim Arbeiten mit der Maschine stets Schutzbrille tragen.
Schutzhandschuhe, festes und rutschsicheres Schuhwerk und
Schürze werden empfohlen.
Späne oder Splitter dürfen bei laufender Maschine nicht entfernt
werden.
Vor allen Arbeiten an der Maschine Stecker aus der Steckdose ziehen.
Maschine nur ausgeschaltet an die Steckdose anschließen.
Anschlußkabel stets vom Wirkungsbereich der Maschine fernhalten.
Kabel immer nach hinten von der Maschine wegführen.
Bei großen Bohrdurchmessern muss der Zusatzhandgriff rechtwinklig
zum Haupthandgriff befestigt werden (siehe auch im Bildteil, Abschnitt
"Handgriff verdrehen").
Bei Arbeiten mit Diamantbohrkronen Schlagwerk ausschalten.
Beim Arbeiten in Wand, Decke oder Fußboden auf elektrische Kabel,
Gas- und Wasserleitungen achten.
BESTIMMUNGSGEMÄßE VERWENDUNG
Der Schlagbohrer ist universell einsetzbar zum Bohren und
Schlagbohren.
Dieses Gerät darf nur wie angegeben bestimmungsgemäß verwendet
werden.
NETZANSCHLUSS
Nur an Einphasen-Wechselstrom und nur an die auf dem
Leistungsschild angegebene Netzspannung anschließen. Anschluss
ist auch an Steckdosen ohne Schutzkontakt möglich, da ein Aufbau
der Schutzklasse
II
vorliegt.
CE-KONFORMITÄTSERKLÄRUNG
Wir erklären in alleiniger Verantwortung, dass dieses Produkt mit den
folgenden Normen oder normativen Dokumenten übereinstimmt.
EN 60745-1:2009 + A11:2010
EN 60745-2-1:2010
EN 55014-1:2006 + A1:2009 + A2:2011
EN 55014-2:1997 + A1:2001 + A2:2008
EN 61000-3-2:2006 + A1:2009 + A2:2009
EN 61000-3-3:2008
gemäß den Bestimmungen der Richtlinien
2011/65/EU (RoHs)
2006/42/EG
2004/108/EG
Winnenden, 2012-09-12
Rainer Kumpf
Director Product Development
Bevollmächtigt die technischen Unterlagen
zusammenzustellen
WARTUNG
Stets die Lüftungsschlitze der Maschine sauber halten.
Nur Milwaukee Zubehör und Milwaukee Ersatzteile verwenden.
Bauteile, deren Austausch nicht beschrieben wurde, bei einer
Milwaukee Kundendienststelle auswechseln lassen (Broschüre
Garantie/Kundendienstadressen beachten).
Bei Bedarf kann eine Explosionszeichnung des Gerätes unter Angabe
der Maschinen Type und der zehnstelligen Nummer auf dem
Leistungsschild bei Ihrer Kundendienststelle oder direkt bei
Milwaukee
Electric Tool, Max-Eyth-Straße 10, D-71364 Winnenden, Germany
angefordert werden.
SYMBOLE
Vor allen Arbeiten an der Maschine Stecker aus
der Steckdose ziehen.
Zubehör - Im Lieferumfang nicht enthalten,
empfohlene Ergänzung aus dem
Zubehörprogramm.
Werfen Sie Elektrowerkzeuge nicht in den
Hausmüll! Gemäss Europäischer Richtlinie
2002/96/EG über Elektro- und Elektronik- Altgeräte
und Umsetzung in nationales Recht müssen
verbrauchte Elektrowerkzeuge getrennt gesammelt
und einer umweltgerechten Wiederverwertung
zugeführt werden.
Schutzklasse II, Elektrowerkzeug, bei dem der
Schutz gegen elektrischen Schlag nicht nur von
der Basisisolierung abhängt, sondern in dem
zusätzliche Schutzmaßnahmen, wie doppelte
Isolierung oder verstärkte Isolierung, angewendet
werden.
Die angegebenen Daten gelten für eine Ausführung mit 230-240 V. Bei Abweichung der Netzspannung sind die auf dem Leistungsschild
aufgeführten Daten gültig.
Summary of Contents for HEAVY DUTY B2E 16 RLD
Page 3: ...4 5 SB2 35 D 13 6 7 10 12 14 8 9 11 ...
Page 4: ...6 7 1 2 3 1 2 3 4 ...
Page 5: ...8 9 1 2 3 4 2 3 30 30 30 1 ...
Page 6: ...10 11 1 2 3 4 START START STOP STOP ...
Page 7: ...12 13 A G SB2 35 D SB2 35 D ...
Page 8: ...14 15 ...
Page 22: ...42 43 ...