11
1.
2.
3.
Squaring the Blade (90°) to the Table (0° Bevel)
Remove battery pack.
Move the bevel adjustment lever to the middle
position and wedge in a tool (screw driver etc.)
so the handle stay in the middle position. Move
the saw head so that the bevel detent mechanism
locks into the 0° bevel detent.
WARNING
Chemical Burn Hazard.
This device contains a
Cleaning
Clean dust and debris from vents. Keep handles
clean, dry and free of oil or grease. Use only mild
soap and a damp cloth to clean, since certain clean-
ing agents and solvents are harmful to plastics and
other insulated parts. Some of these include gasoline,
turpentine, lacquer thinner, paint thinner, chlorinated
cleaning solvents, ammonia and household deter-
combustible solvents around tools.
Repairs
For repairs, return the tool, battery pack and charger
to the nearest service centre.
ONE-KEY™
4. Place a square against the table and blade and
ensure that the square is not touching blade teeth
as this will cause an inaccurate measurement.
5. Loosen 2 screws (T25) on the front of the bevel arm,
these screws are used to clamp the detent body.
6. Using a T25 wrench you can adjust the bevel set-
ting of the blade-to-table. Clockwise tilts blade to
the right, counterclockwise tilts blade to the left.
7. When you have the blade set to the 0° bevel,
torque the 2 screws to 10-12 Nm.
8. Remove the tool used to wedge the bevel adjust-
ment lever.
9. Move the bevel adjustment lever to "lock".
assembly, tightening the screws securely.
11. If necessary, loosen the left and right bevel
pointer adjustment screws and reposition the
pointers the so that they indicates exactly zero.
Once the pointers are properly positioned, re-
tighten the bevel pointer adjustment screw.
WARNING
T
jury and
o reduce the risk of personal in
damage, never immerse
-
your tool, battery pack or charger in liquid or
lithium button/coin cell battery. A new
or used battery can cause severe in-
ternal burns and lead to death in as
securely.
ACCESSORIES
little as 2 hours if swallowed or enters the body.
Always secure the battery cover. If it does not
close securely, stop using the device, remove the
batteries, and keep it away from children. If you
think batteries may have been swallowed or
entered the body, seek immediate medical atten-
tion.
Internal Battery
An internal battery is used to facilitate full ONE-KEY™
functionality.
To replace the battery:
1. Remove the battery pack.
2. Remove the screw(s) and open the battery door.
3. Remove the old battery, keep it away from children,
and dispose of it properly.
4. Insert the new battery (3V CR2032), with the posi-
tive side facing up.
5. Close the battery door and tighten the screw
WARNING
Use only recommended accesso-
ries. Others may be hazardous.
For a complete listing of accessories, go online to
www.milwaukeetools.com.au/
www.milwaukeetools.co.nz or contact a distributor.