USER MANUAL

MC745

MILWAUKEE MC311 EC CONTROLLER

WITH TWO MP810 1,5 L/H DOSING PUMPS

SPECIFICATIONS

MC311 EC Meter

Range

  

0.0 to 10.0 mS

Resolution

0.1 mS 

Accuracy  

 

±2% Full scale

Setpoint

   

0.8 to 2.8 mS

Alarm / Output

   active when measure is

Power Socket

  higher/lower than selected

setpoint depending on

user selection

Power drivers

  115VAC, 2A, 60Hz

or 230VAC, 1A, 50Hz

pH electrode

 

MA812/2 (included) 

Environment

 

0 to 50°C, 95% RH 

not condensing

Power supply

  12 VDC (included) 

Dimensions

 

148.5 x 82.5 x 32 mm

Weight

 

180 g

MP810 Peristaltic Dosing Pump

Constant Dosing fl ow of 1,5 l/h

(25 cc/min)

• No regulation

• Maximum pressure: 1 bar

Made of Polipropilene (PP)

Peristaltic tube in Santoprene

Power supply: 230 VAC ± 10%

Authorized Distributor in Australia

Pacific Sensor Technologies Pty Ltd

Unit 4, 3 Neutron Place Rowville, VIC 3178 Australia

1300 662 720 | sales@pacificsensortech.com.au

www.pacificsensortech.com.au

Summary of Contents for MC745

Page 1: ...30VAC 1A 50Hz pH electrode MA812 2 included Environment 0 to 50 C 95 RH not condensing Power supply 12 VDC included Dimensions 148 5 x 82 5 x 32 mm Weight 180 g MP810 Peristaltic Dosing Pump Constant Dosing flow of 1 5 l h 25 cc min No regulation Maximum pressure 1 bar Made of Polipropilene PP Peristaltic tube in Santoprene Power supply 230 VAC 10 Authorized Distributor in Australia Pacific Sensor...

Page 2: ... higher or lower than selected setpoint depending on user selection When the alarm is activated it also activates the connection base and the auxiliary equipment The setpoint can be selected by adjusting the central front knob to the desired value The selectable range is from 0 8 to 2 8 mS Connect the supplied 240VAC 12VDC power adapter to the meter and to the main line Connect the connection base...

Page 3: ...y to inject into a piping This fitting has a thread that links it to the piping The calibration is now complete and the meter is ready for use The instrument should be re calibrated at least once a month or when the probe is changed Mount the bracket in the wall in upright position above the water container which contains a solution of EC reducing acid and water Place the pump in vertical position...

Page 4: ...roneous operation by the user please return the parts to either dealer or our office and the repair will be effected free of charge Note We reserve the right to modify the design construction and appearance of our products without ad vance notice IMPORTANT For a smooth adjustment of the EC of your nutrient mix it is advisable to dilute each liquid nutrient with water in a jug Example For a 100 lit...

Reviews: