4-3
1
1
1
4
Register Mark Reading
Functions
Precautions when Creating Data with Register Marks
Permitted Arrangements of Register Marks and the Design
Starting position of TP1 should be more than 10mm away from the end of workpiece and place within 10mm
from maximum cutting area.
The possible range of design placement is 610x510mm at maximum.
Prohibited Drawing Areas around Register Marks
Ensure that the areas around the register marks (area equivalent to the register mark size from the register mark
origin) remain free of data and dirt. Otherwise, false detection or incorrect reading of the register marks may occur.
• When place a register mark outside the cut area (the end of the workpiece), turn on the setting of
MARK FILLUP. (
Mark Form :
Type 1
Mark Form :
Type 2
• False detection of the register marks causes displacement of the cutting position.
Work piece
More than 10mm from
left end of work piece
Maximum effective
cutting area
Permitted Arrangements
More than 10mm from
left end of work piece
Cutting
area
Type1
Work piece
More than 10mm from
left end of work piece
Permitted Arrangements
Maximum effective
cutting area
More than 10mm from
left end of work piece
Cutting area
Type2
Mark size
Mark Form : Type 1
No-plotting area
Mark
Mark Origin
No-plotting area
Mark
Mark Origin
Mark Form : Type 2