4-11
1
1
1
4
Register Mark Reading
Functions
Detecting Register Marks
Setting height of register mark
Reading the register mark and set the height of the sensor.
1
Move the mark sensor on top of the register mark
with the jog key.
2
Loosen the thumbscrew.
3
Lower the lever to a height that the gauge shaft
contacts the register mark.
4
Tighten the screw while the height guage shaft is
in contact with the register mark and release the
hand from the lever.
• Until tighten the screws, hold it lowered the lever.
• After cutting the data with mark sensor, lift up the mark sensor. When set a felt mat while lowering the
mark sensor, the set guide plate may be hit by the head and may cause the head damage.
• Make sure that the height gauge shaft is in
contact with the register mark.
• Use always lever for vertical movement of
the mark sensor. If do with the
thumbscrew, it will not be in the correct
height.
• Make sure that the lever is raised.
• Firmly fix thumbscrew.
Register mark
Mark sensor
Thumbscrew
Lever
Summary of Contents for CFL-605RT
Page 7: ...vi ...
Page 14: ...xiii ...
Page 48: ...2 8 1 Put the workpiece on the cutting panel 2 Press ...
Page 68: ...2 28 ...
Page 138: ...4 22 ...
Page 168: ...6 24 ...
Page 169: ...D202786 14 30062016 ...