Plotting Function of Mechanical pencil
Grouping function
Whenever the tool operation mode is selected to the automode, the Mechanical pencils having
the same lead diameter deems as a group. When any pen No. in the group is assigned, from the
Mechanical pencil in the lowest magazine No. will be started using earlier. Therefore even if a
command to replace the the magazine No. with another magazine No. in the group is received,
the replacement would not be executed. The control system allows to continuously use the same
Mechanical pencil until all read will be all useed.
Detecting Function for Existence of Lead
The residual lead is monitored all the time, and the lead is extended by knocking during plotting
operation. When the monitor detects the end of lead extension after a knocking or during plotting,
the wasted lead is exhausted and new lead is supplied by the lead feeding system. If the lead
feeding operation can not supply the lead, the Mechanical pencil will be returned to the magazine.
Under the automode, another Mechanical pencil filled with the same lead diameter, if any in the
magazine, is automatically takes the place, and the plotting can be continued. When all leads
have been used (under the automode) or the lead in the assigned Mechanical pencil has been
used (under the manual mode), the message indicating to require supply of the lead will be
appeared on the display panel.
Under the automode
Under the manual mode
The Mechanical pencil(s) filled with new leads shall be set in the magazine and returned to the
plotter. The plotter interpretes the applicable pen, and restores to start plotting again.
To perform plotting with the speed, acceleration and pressure established
on the host computer, set the tool operation mode to the manual mode.
If the auto operation mode is selected, the plotter will ignore the settings
transmitted from the host computer.
THE TOOLS
X . X m m P E N C I L N O L E A D
P E N X N O L E A D
Summary of Contents for cg-100AP
Page 16: ...xiv ...
Page 70: ...1 54 ...
Page 108: ...2 38 ...
Page 145: ...CHAPTER 4 SELF DIAGNOSIS FUNCTION 4 9 DEMONSTRATION PATTERN 1 2 Demonstration Pattern 1 ...
Page 146: ...4 10 Demonstration Pattern 2 ...
Page 173: ...CHAPTER 6 APPENDIX 6 13 Table of 82 special character codes supported ...
Page 179: ...D200310MAC 2 00 09061999 ...
Page 180: ... MIMAKI ENGINEERING CO LTD 1999 6 Printed in japan ...