2-12
3
Select [PARAM], and the following
display will be appeared.
4
Select [PEN PARAMETER], and the
following display will be appeared.
5
Select the pen No. to be established.
The No. is changed whenever the
key is depressed. Display the appli-
cable pen No.
-F1
: All data, and from Data No.1 to No.8.
If it is required to unify all of the tools conditions in the magazine, select the
all data. If it is established by each pen, display the applicable No.
6
Change the values of [ACC], [SPD]
and [FORCE]. The value is changed
whenever the key is depressed.
Display the objected value.
-F2+
(ACCELERATION) : 0.3, 1.0, 2.0, 3.0, 4.0, 5.7
-F3+
(SPEED) : 2, 5 - 85 (5 step), 120cm/s
(The maximum speed is 60 cm/s when a roll paper is used.)
-F4+
(FORCE) : 15, 20 - 450g (10 step)
When other pen No. is to be continuously established, re-
turn to the Step 5 above, then repeat the operation thereaf-
ter.
7
When all establishments have com-
pleted, accomplish the registration.
The display returns to the first page
of the menu.
END
<--CLEAR AUTO CUT-->
<--PEN SET HALF CUT-->
CUTTER PARAMETER
PEN PARAMETER
-F4+
ALL-DAT ACC:2.0
SPD: 20 FORCE: 20
-F3+
Summary of Contents for cg-100AP
Page 16: ...xiv ...
Page 70: ...1 54 ...
Page 108: ...2 38 ...
Page 145: ...CHAPTER 4 SELF DIAGNOSIS FUNCTION 4 9 DEMONSTRATION PATTERN 1 2 Demonstration Pattern 1 ...
Page 146: ...4 10 Demonstration Pattern 2 ...
Page 173: ...CHAPTER 6 APPENDIX 6 13 Table of 82 special character codes supported ...
Page 179: ...D200310MAC 2 00 09061999 ...
Page 180: ... MIMAKI ENGINEERING CO LTD 1999 6 Printed in japan ...