CHAPTER 2
BASIC OPERATION
2-13
ESTABLISHMENT OF THE TOOLS CONDITIONS
Setting the cutter parameters
1
The first page of the menu will be
displayed.
2. Select [PEN SET], and the following
display will be appeared.
3
Select [PARAM], and the following
display will be appeared.
4
Select [CUTTER PARAMETER], and
the following display will be ap-
peared.
5
Change the values of [SPD],
[FORCE] , [ACC] and [OFSET]. The
value is changed whenever the key is
depressed. Display the objected
value.
-F1+
(SPEED) : 2, 5 - 85 (5 step), 120cm/s
(The maximum speed is 60 cm/s when a roll paper is used.)
-F2+
(FORCE) : 15, 20 - 450g (10 step)
-F3+
(ACCELERATION) : 0.3, 1.0, 2.0, 3.0, 4.0, 5.7G
-F4+
(OFSET) : 0.00 - 2.50mm (0.05 step)
6
When all establishments have com-
pleted, accomplish the registration.
The display returns to the first page
of the menu.
-PAGE+
<--CLEAR AUTO CUT-->
<--PEN SET HALF CUT-->
-F3+
<--SAVE NO. :#1 ASSIGN-->
<--MODE:MANUAL PARAM-->
CUTTER PARAMETER
PEN PARAMETER
-F4+
ALL-DAT ACC:2.0
SPD: 20 FORCE: 20
-F3+
END
<--CLEAR AUTO CUT-->
<--PEN SET HALF CUT-->