CHAPTER 4
SELF DIAGNOSIS FUNCTION
4-5
DUMP TEST
• The dump test can not be achieved under the pause mode.
• When the dump test is discontinued, "data clear" (P.3-4) must be accom-
plished.
Plot the receiving data with ASCII data, then verify the data for an abnormal state. The character shall be about
5mm square in size.
The control code plots with two hexadecimal character in the 5mm suare.
The characters differ in size in accordance with the scale setting.
The test shall be achieved by setting the pen and leaf paper or roll paper of A2 and over.
1
Set the pen in the magazine No.1,
then install onto the main unit.
Refer to Chapter 2 "Preparation of
the Tools" (P.2-21).
2
Set the paper.
Refer to Chapter 2 "PAPER SET-
TING" (P.2-25).
3
Select the offline mode.
Execute Chapter 3 "DATA CLEAR"
(P.3-4).
4
Display the fifth page of the menu.
5
Select [DUMP], and the following
display will be appeared.
6
Transmit the data from the host
c o m p u t e r .
Plot the receiving data with ASCII
data. The following display will be
appeared during the plotting.
7
The dump test is ended and returned
to the first page of the menu.
-PAGE+
<--SELFTEST PRM-LIST-->
<--LINE : OFF DUMP-->
-F4+
DUMP START
- F2+
DUMP) # X
XXXg XXXcm X. XG
<--CLEAR AUTO CUT-->
<--PEN SET HALF CUT-->
Summary of Contents for cg-100AP
Page 16: ...xiv ...
Page 70: ...1 54 ...
Page 108: ...2 38 ...
Page 145: ...CHAPTER 4 SELF DIAGNOSIS FUNCTION 4 9 DEMONSTRATION PATTERN 1 2 Demonstration Pattern 1 ...
Page 146: ...4 10 Demonstration Pattern 2 ...
Page 173: ...CHAPTER 6 APPENDIX 6 13 Table of 82 special character codes supported ...
Page 179: ...D200310MAC 2 00 09061999 ...
Page 180: ... MIMAKI ENGINEERING CO LTD 1999 6 Printed in japan ...