4-4
Troubles for which error messages are given on the LCD
Error message
Error messages are shown as error numbers.
Take an appropriate remedy according to the table below. And if the remedy does not work, contact your
distributer or an sales office of MIMAKI.
Error message
Cause
Remedy
ERR02 MAIN RAM
Trouble has occurred in the control
RAM.
Contact your dealer or a sales office of
MIMAKI.
ERR04 EEPROM
Trouble has occurred in the system
ROM.
ERR06 BUFFER
Trouble has occurred in the receiver
buffer.
ERR08 POWER
Trouble related to the motor has
occurred.
ERR10 COMMAND
Code other than command data has
been received.
Check the command setting on the
host computer.
ERR11 PARAMETER
A parameter outside the numerical
range has been received.
Check the parameter.
ERR12 DEVICE
The plotter received an improper
device control command.
Check the command setting on the
host computer.
ERR13 PM OVER
Data on polygon has overflown the
polygon buffer.
Change the setting so that the polygon
command is not used or the MGL-lc1
command is to be used.
ERR15 AUTO FEED
The plotter has failed to feed the
sheet by the length specified by the
ZX command.
After completion of sending the data
from the host computer, reload the long
sheet and execute the plural sheets
cutting.
During division cutting, the plotter has
failed to feed the sheet for cutting
based on the second and ubsequent
data by the same length as for the
first cutting.
Load a longer sheet on the plotter and
set the remote mode again.
ERR16 AUTO I/F
The plotter has failed to detect a
command automatically.
Set the command name.
(
P.3-65
)
ERR27 BUFFERover
The interface is faulty.
Check the interface cable.
ERR30 OPERATION
An invalid operation was performed
on the control panel.
Refer to the relevant page of operation
manual for valid operations.
ERR31 NO DATA
The plotter started the plural sheets
cutting but found that there is no data
in the receiver buffer.
Refer to the explanation of the plural
sheets cutting function.(
P.3-10
)
ERR32 DATAtooBIG
The amount of received data is too
large for the plotter to perform the
plural sheets cutting.
ERR33 SHEET SIZE
The sheet is too short in the feeding
direction.
Use a longer sheet.
ERR34 DAT REMAIN
The plotter executed an improper
operation during a halt.
Press the
key to cut the
remaining data or execute data clear if
there is no need of using the data in
the receiver buffer.(
P.3-54
)