3-18
Set for Detecting the Registration Marks
When you want to cut the data with registration marks, you must set the following without fail.
1
Press the
key in the local
mode.
2
Press the jog key
or
to select
[SET UP] .
3
Press the
key.
4
Press the jog key
or
to select
[MARK DETECT] .
5
Press the
key.
6
Press the jog key
or
to select
[Number of detected registration
marks].
• Set values: OFF, 1pt, 2ptA, 2pt B, 3pt, and 4pt
7
Press the
key.
• In case you selected “OFF” in Step 6, proceed to Step 12.
8
Press the jog key
or
to select the following items.
• The following items are provided for the setting of registration mark detection:
Scale compensation, registration mark size, offset A, offset B, form of registration mark,
number of continuous cutting in direction A, number of continuous cutting in direction B,
high speed limit, skew check, and detect mode
• See pages P.3-19 through P.3-22 for the contents of each setting item.
D A T A
C L E A R
< E N T >
FUNCTION
S E T
U P
< E N T >
ENTER/HOLD
M A R K
D E T E C T < e n t >
M A R K
D E T E C T : O F F
ENTER/HOLD
M A R K
D E T E C T : 2 p t A
ENTER/HOLD
Summary of Contents for CG-60SR
Page 1: ...D201611 16 MIMAKI ENGINEERING CO LTD URL http www mimaki co jp...
Page 5: ...iv...
Page 14: ...xiii...
Page 141: ...Function Flowchart 5 15 5 Appendix FORM TYPE1 4 40 SPEED 1 0 cm s TYPE1 TYPE2...
Page 142: ...5 16...
Page 143: ...D201611 16 30112011...