3-29
Cut Out Data with Registration Mark
3
Use
ful Func
tion
Detecting procedure ( [DIST.REVI.] Setting value is “BEFOR”)
1
Follow steps 1 to 3 of "Detecting procedure ( [DIST.REVI.] Setting
value is “BEFOR”)" (
P.3-27)
2
Press the
key.
• The plotter will start detecting the registration
marks according to the settings of [MARK
DETECT].
• See "Setting the Number of Registration Mark Detection"
(
P.3-19
)
for the number of
registration marks.
• In case the plotter cannot detect any registration marks, it displays “Error 36 in the
registration mark detection” on the display. Set the sheet again.
3
After the detection of the registration
marks, the scale compensation display
appears.
• The right figure shows the 4-point detection display as an example.
• If there is a difference between the actually measured value and the detected length,
make setting with the jog key
or
.
• Press the
key to change the display to the next scale compensation setting.
• If [DIST.REVI.] is set to [OFF], the display for scale compensation setting will not appear.
• If [MARK DETECT] is set to [2ptA], the display for inputting the B length will not appear.
• If [MARK DETECT] is set to [1pt], the scale compensation setting display will not appear
but the origin point will be displayed.
4
Press the
key after
completing the settings.
• Set the origin.
• The display will show the available cutting area
and then return to local mode.
* * M A R K
D E T E C T * *
ENTER/HOLD
A ( 1 - 2 ) = * * * . *
ENTER/HOLD
* *
O R I G I N
* *
A = * * * *
B = * * * *
C U T 1
2 0
0 5 0
0 . 3 0
ENTER/HOLD