3-36
8
By pressing the jog keys
and
, adjust the light
pointer position so that the center of the light pointer is in alignment
with the center of the cross pattern.
9
Press the
key.
• The plotter will return to the local mode after
registering the compensation value.
Adjust the sensitivity (light intensity) of the mark sensor LED (automatically)
If an error occurs frequently in registration mark detection, a possible cause is an improper sensitivity of the
mark sensor LED.
In this case, adjust the sensitivity (light intensity) of the mark sensor LED.
1
Make sure that the plotter is in local
mode.
2
Confirm that the mark sensor is located
just above a plain area (non-printed
area) of the sheet.
• If the mark sensor is not located just above a plain
area, correct the location with jog keys
and
.
3
Press the
key.
• The value registered in the [POINTER OFS] is not initialized even by executing the [SETUP
RESET].
• Make sure that the sheet is clean and white, and locate the sheet directly under the sensor.
C U T 1
2 0
0 5 0
0 . 3 0
ENTER/HOLD
C U T 1
2 0
0 5 0
0 . 3 0
D A T A
C L E A R
< E N T >
FUNCTION