- 4.5 -
Setup functions
The FUNCTION mode consists of 14 items.
The following describes the overview of and settings for each function.
Print Mode
Sets the plot quality, plot direction.
Quality
: Select the quality image from three items.
[STD]
:
Standard image quality
[FINE]
:
High image quality and low plotting speed
[High SPD]
:
High plotting speed and slightly inferior image quality
DIRECTION: Specifies the head movement direction along which plotting is made.
[UNI-D]
:
Specifies that plotting is made while the head is moving to the left.
[BI-D]
:
Specifies that plotting is made while the head is moving to the left
and right.
This mode allows higher plotting speed with a lower plot quality
than UNI-D.
Return SPD: The unidirectional plot within 1000mm width may cause nozzle drop-
out. Nozzle drop-out can be solved by head’s return at low speed.
[NORMAL]
:
The head returns at normal speed.
[SLOW]
:
Make the head return at low speed.
LOGICALseek: Normally, the head moves all the way to both ends of the media to
make plotting.
With LOGICAL seek, the head moves to the left and right according
to the width of the plot image to make plotting.
This can reduce the plotting time.
The head movements are shown below.
OFF (UNI-DIRECTIONAL) OFF (BI-DIRECTIONAL)
Summary of Contents for DM3-1810S
Page 2: ......
Page 20: ... xvi ...
Page 34: ... 1 14 ...
Page 76: ... 3 20 ...
Page 112: ... 6 10 ...
Page 131: ... A 19 TYPE Refresh Level3 TYPE mm inch mm X Level0 Level3 X inch Function flowchart ...
Page 141: ... A 29 MAIN Ver1 00 I F Ver Function flowchart ...
Page 144: ...D201258 1 10 30032007 ...
Page 145: ......
Page 146: ...PrintedinJapan MIMAKI ENGINEERING Co Ltd FW 5 10 NH ...