- 6.8 -
Error messages
Error messages indicates error numbers.
If any error message is given on the LCD, turn off the power to the device and turn it on after a while.
If the same error message appears again on the LCD, contact your local MIMAKI distributor or
MIMAKI office to call for service.
Error message
Cause
Corrective measure
ERROR 01
MAIN ROM
ERROR 02
MAIN RAM
ERROR 03
POWER +5V
ERROR 04
FRASH ROM
ERROR 06
D-RAM
ERROR 07
HEAD
−
−
∗
−
−
−
−
−
ERROR 08
ENCODER n
ERROR 09
HDC
ERROR 10
COMMAND
ERROR 11
PARAMETER
ERROR 13
CONNECT RIP
ERROR 15
OFF SCALE
Control circuit board is defective.
Control circuit board is defective.
POWER+5V
POWER+35V
Control circuit board is defective.
Head connection failure is
detected.
Trouble with detection of linear
encoder.
Control circuit board is defective.
FPGA Error
HDC Error
The device has received data
other than command data.
The interface cable used is not in
conformance with this plotter.
A parameter outside the range of
acceptable numeric values is
received.
Turn off the power to the device
an turn it on after a while. If the
same error message appears again
on the LCD, contact your local
distributor to call for service.
Securely connect the interface
cable in position. Use an interface
cable in conformance with the
standard.
Turn off the power to the device
and turn it on after a while. If the
same error message appears again
on the LCD, contact your local
distributor to call for service.
Received data from the RIP
unable connect to the device.
Received data out of x-direction.
Send data from the RIP avail-
able on the device. For detail
information on the RIP, refer to
your local distributor.
Send data included in print area.
Summary of Contents for GP-604D
Page 2: ......
Page 18: ...xiv...
Page 54: ...2 24...
Page 80: ......
Page 106: ...5 26...
Page 122: ...A 6...
Page 133: ......