- 5.10 -
8.
Remove the ink at the wiper and the bracket
using a cotton bud dampened with cleaning
fluid RS.
•
If dirt of curl is serious, replace the wiper with a
new one. At the time of replacement, be sure to
terminate the plotter operation and follow the
wiper replacement procedure.
9.
Holding the projections at both ends, insert the
wiper which has cleaned into place.
10. Push the [ENTER] key.
11. Fill the cap with the cleaning fluid using a
dropper.
12. Close the front cover, and push the [ENTER]
key.
13. Press the [ ] and [ ] key, select the time to
leave. (1-99 mins: 1 min unit)
Normally set 1 min.
14. Push the [ENTER] key.
The indication at the right display continues during selected
time to leave for sucking the cleaning solution and cleaning.
15. Return to the LOCAL mode.
STATION
TIME
: 1 min
INITIALIZING
PLEASE WAIT
< LOCAL >
Fill the Liquid.
COMPLETED