background image

Make sure to wear the attached 

goggles and glove

 when you work.

JFX200-2513 / JFX500-2131

Cleaning procedure of head nozzle

Only when the nozzle drop out doesn’t recover with cleaning, daily care and maintenance, please clean
the head nozzle following the procedure below.

Procedure

1. Remove the left side cover of

the machine.

Remove  the  screw  and  remove  the
cover.

2. Move the carriage(head) to the maintenance space.

(1) Press the 

 key in LOCAL.

(2) Press the 

 key.

(3) Press 

 to select [HEAD MAINT.].

(4) Press the 

 key.

• Before performing the maintenance, please make sure to attend the training by our engineers. Maintenance 

without training may cause failure of the head.

• During maintenance, never rub the nozzles of the head. If rub the nozzle part, the water-repellent surface is 

degraded and the head might need to be replaced.

Supply goods for cleaning

Nozzle swab (100)

Cleaning stick (50)

F200/LF200 Cleaning liquid

for maintenance (100mℓ)

No.SPC-0421

No.SPC-0527

No.SPC-0568

• Make sure to use designated supply goods for nozzle cleaning. Other cleaning goods may cause early 

deterioration of the head.

• Head will move for maintenance, please be careful.

[JFX200] Remove the screws 

at two positions.

[JFX500] Remove the screws 

at four positions.

Cover

Cover

MAINT.