background image

© 2016 MIMAKI ENGINEERING CO., LTD.        M018365-00(D203018-10)-15042016

3. Wet  a  new  “nozzle  swab”  or  “clean  stick”  with  the  cleaning

solution.

Please wet enough the cleaning solution.

4. Clean the nozzle surface.

(1) Press  the  "nozzle  swab"  or  "cleaning  stick",  absorbing  cleaning  liquid,

against nozzle surface softly for about 10  seconds.

(2) Perform the work (1) to the entire nozzle surface.

5. Press the 

 key after the cleaning.

After initial operation, carriage (head) return to the original position.
Please close the cover.

6. Implement the cleaning [NORMAL].

Please operate with reference to Chapter 4 of the Operation Manual.

7. Perform test printing and check the print result.

Repeat the cleaning and test printing until the result becomes normal.

• Please do not reuse the used clean stick.

It may cause nozzle clogging.

• Please do not rub the nozzle surface and press down strongly 

sponge part with your fingers. Nozzle surface is damaged, and it 
may cause the discharging defects.

• Please do not re-use the clean stick which was used once. Always 

use a new clean stick seconds.

Press softly for 10 seconds

Nozzle surface

KT