- 3.2 -
Routine Maintenance
Be sure to conduct maintenance works for the device when necessary or periodically so as to use the
device for a long time while keeping its plotting accuracy.
Notes on cleaning
• When using the maintenance cleaning fluid RS, be sure to wear the protec-
tive glasses.
• Never disassemble the device. Disassembling the device can result in
electric shock hazards and breakage of the device.
• Prevent moisture from entering inside the device. If the inner part of the
device becomes wet, electric shock hazards and breakage of the device can
result.
• Conduct maintenance works after turning off the power switch and detach-
ing the power cable. If not, unexpected troubles can arise.
• Do not wipe the nozzles, wiper, or cap of the head with water of alcohol as
doing so may cause nozzle clogging or damage to nozzles.
• Do not use benzine, thinner and chemical agents containing abrasives.
Such materials can deteriorate or deform the surface of the cover.
• Do not apply lubricating oil or the like inside the device. Such materials can
cause the plotter mechanism to fail.
• Be careful not to allow the maintenance cleaning fluid RS or ink to adhere to
the cover as this may cause deterioration or discoloring of the surface of the
cover.
Summary of Contents for JV3-130 SP II
Page 2: ......
Page 34: ... 1 16 ...
Page 120: ... 5 32 ...
Page 130: ... 6 10 ...
Page 136: ... A 6 ...
Page 137: ......
Page 143: ......
Page 144: ...Printed in Japan MIMAKI ENGINEERING Co Ltd 2004 ...