- 6.10 -
ERROR 23
HOST I / F
ERROR 24
I / F INITIAL
ERROR 30
OPERATION
ERROR 34
DATA REMAIN
ERROR 40
MOTOR X
ERROR 41
MOTOR Y
ERROR 42
X CURRENT
ERROR 43
Y CURRENT
ERROR 46
WIPER
ERROR 50
MEDIA SENSE
ERROR 51
Y ORIGIN
ERROR 57
HEAD HIGHT SENS.
HOST I/F Timeout error has
arisen during communication
between the host computer
and interface board.
Initial operation failure of the I/
F board and control board.
An error occurs on the inter-
face between the I/F board
and the control board.
Settings for functions have been
tried to be changed though there
remains received data that has
not yet been printed.
The Xmotor has been overload.
The Ymotor has been overload.
Overcurrent error on the
Xmotor has been detected.
Overcurrent error on the
Ymotor has been detected.
Check to be sure that the cable
is securely connected to the
host computer and interface
board. Also, check to ascertain
that no error has arisen on the
host computer side.
Turn off the power to the device
and turn it on after a while. If the
same error message appears
again on the LCD, contact your
local distributor to call for service.
Perform a proper operation.
Print all pieces of received
data or execute the data clear
function. Then, change the
settings.
Turn off the power to the
device and turn it on after a
while. If the same error
message appears again on the
LCD, contact your local dis-
tributor to call for service.
Error message
Cause
Corrective measure
The wiper position is not
correct.
Paper could not be detected.
The media set position or
media itself is not correct.
Origin could not be detected.
Head height could not be
detected.
Turn off the power to the
device and turn it on after a
while. If the same error
message appears again on the
LCD, contact your local dis-
tributor to call for service.
Refer to “Setting the media”.
page 2.8.
If this error cannot be resolved
even after setting it correctly,
contact the dealer.