- 4.4 -
Function mode
The FUNCTION mode consists of 18 items.
The 18 items can be registered for each of the following four types.
If the type has been registered for each media type, it becomes easy to change plotting
conditions when the media type is changed.
Example)
Type1
:
For Tarpaulin 1
Type2
:
For Tarpaulin 2
Type3
:
FF
Type4
:
PVC
Registering a type
1.
Make sure that the mode is LOCAL mode.
2.
Press the [FUNCTION] key.
3.
Press the [ENTER] key.
4.
Press the Jog key [ ] or [ ] to select any of
Types 1 through 4.
5.
Press the [ENTER] key.
Setting Plotting conditions.
page 4.5
Changing the type
If plotting conditions for types 1 through 4 have already been registered, settings can be
selected according to the plotting simply by selecting the type.
1.
Perform steps 1 through 5 above.
Select a type.
2.
Press the [END] key.
Plotting with the plotting condition registered for the selected
type is possible.
< LOCAL >
Width : 1272 mm
FUNCTION
SET UP
< ENT >
SET UP
SELECT
: TYPE . 1
SET UP
SELECT
: TYPE . 2
TYPE . 1
MEDIA COMP.
< ent >
TYPE . 1
MEDIA COMP.
< ent >