STEP
1.
Push the [FUNCTION] key.
2.
Push the [ ] and [ ] key until the display gives
the indication [MAINTENANCE].
3.
Push the [ENTER] key.
[STATION] is displayed.
4.
Push the [ENTER] key.
[CARRIAGE out] is displayed.
5.
Push the [ENTER] key.
Move the carriage on the platen.
6.
Open the front cover.
7.
Dampen a cotton bud with cleaning fluid.
8.
Using the cotton bud dampened with cleaning
fluid, wipe out dirt on the wiper and around the
cap.
•
Be careful not to leave lint of the cotton bud. Lint
may cause plotting failure.
9.
Close the front cover, and push the [ENTER]
key.
The carriage return to the capping station, and the initial
operation is performed.