- 2.3 -
Switching on the power supply
The device is provided with the following two different power switches.
Main power switch
:
Located on the rear face of the device. Normally, leave this switch turned on.
If this switch is left turned off, the head nozzles may be clogged. Nozzle clogging
may not be recovered depending on the symptom.
•
When the main power switch is turned ON with the power switch
set to OFF, the nozzle clogging preventive function operates.
After operation, the power is turned OFF automatically.
Power switch
: Located on the front face of the device. Normally, use this switch.
Press this switch once to turn on the power of the device. Press it again to turn off
the device. Even when the power switch is off, the power is turned on periodically
and the nozzle clogging preventive function is activated.
Turning the power on
1.
Turn on the power to the device.
Tilt the power switch toward the “ I ”side.
• Make sure that the front cover is closed.
If it is open, initialization is not performed.
When the power is switched on, the LCD first displays
“BOOT” and then displays the firmware version number.
2.
The message “PLEASE WAIT” appears flash-
ing on the LCD.
The initial operation of the device is performed.
3.
The device enters the LOCAL mode.
If a medium has been set on the device, the prompt Media
Select is displayed on the LCD.
4.
Turn on the power to the computer which is
connected to the device.
BOOT
V X.XX
PLEASE WAIT
< LOCAL >
MEDIA SELECT
ROLL <
> LEAF