- 2.24 -
Correcting the medium feed rate during operation
In the “MEDIA COMP.”, operations are in a local mode. (
page 2.22).
The following describes the procedures altering the medium feed rate during operation or in a
Remote mode.
STEP
1.
Press the [REMOTE] key.
2.
Press the [FUNCTION] key to confirm the
current setting value.
Press the [END] key when an appropriate value is set or to
abort an operation.
3.
Press the [ENTER] key.
Available to alter the medium feed rate.
4.
Press the jog key [ ] or [ ] as needed to set
the amount of correction.
The value is incremental/ decremental to the correction value
of the current media type.
• A new value takes effect in real time. The best
effect can be obtained while checking the result.
• The unit of the correction value is the same as in
“MEDIA COMP.” in the LOCAL mode.
(
page 2.22)
5.
Press the [ENTER] key.
Confirm the medium feed rate before saving it.
Press the [END] key to return to the REMOTE display.
The altered value ceases to be in effect, and returns to the
previous value.
6.
Press the [ENTER] key to return to the RE-
MOTE display.
Save the altered medium feed rate. The saved feed rate is
effective in the next power on. In case altering the setting on
the main unit, it displays “+” after the TYPE. Number.
Press the [END] key to save the value contemporary. Make
sure the value ceases to be in effect performing media
detection and invalid in the next power on.
∗
REMOTE
∗
TYPE. 1
0. 0 0m
FEED COMP.
0
FEED COMP.
0
1
correction
value
current value
∗
REMOTE
∗
TYPE. 1+
0. 0 0m
FEED COMP.
SAVE
: ent
FEED COMP.