- 3.4 -
Cleaning the wiper and ink caps
The ink cap prevents clogging of the head nozzle caused by dried nozzle.
The wiper wipes out ink adhered to the head nozzle.
As the device is used to plot images, the wipers and ink caps gradually become stained with ink and
dust.
Use the cotton buds to clean the ink and wiper.
Clean the wiper and the ink cap periodically so as to keep the plotter in good operation condition.
• When cleaning the ink station and head, be sure to wear the supplied
goggle and gloves since you may get ink in your eyes.
• Do not move the carriage out of the capping station by hand. Use the appro-
priate operation key to move the carriage.
STEP
1.
Push the [FUNCTION] key.
2.
Push the [ ] and [ ] key until the display gives
the indication [MAINTENANCE].
3.
Push the [ENTER] key.
[STATION] is displayed.
4.
Push the [ENTER] key.
[CARRIAGE out] is displayed.
5.
Push the [ENTER] key.
Move the carriage on the platen.
6.
Open the front cover.
7.
Holding the projections at both ends, draw out
the wiper.
FUNCTION
SET UP
< ENT >
FUNCTION
MAINTENANCE
< ENT >
MAINTENANCE
STATION
< ent >
STATION
MENT : CARRIAGEout
STATION
COMPLETED
: ent