© 2014 MIMAKI ENGINEERING CO.,LTD.
7.1.2
P.3
7.1.2 List of Error Messages
1
2
3
4
5
6
7
8
36
ERROR 401
MOTOR X
X Servo error
(Excessive load to the X-motor)
1. Check if there is no error on the print data.
(Check if the same error occurs on other data?)
2. Check if there is no trouble on the Timing Belt.
3. Check if there is no trouble on the Motor Cable.
(disconnecting, burnout, or the like)
4. Check the FFC between each PCB and Short-
connectors connected on the PCB.
5. Replace the X-axis Motor with a new one.
(Refer to
3.2.1)
37
ERROR 403
X CURRENT
X-motor current
(Over current error of X-motor is detected.)
38
ERROR 402
MOTOR Y
Y Servo error
(Excessive load to the Y-motor)
1. Check if there is no error on the print data.
(Check if the same error occurs on other data?)
2. Check if it moves to the Y-direction smoothly in the
power-off condition.
3. Check if there is no trouble on the Timing Belt.
4. Check if there is no trouble on the Motor Cable.
(disconnecting, burnout, or the like)
5. Check the FFC between each PCB and Short-
connectors connected on the PCB.
6. Replace the Y-axis motor with a new one.
(Refer to
3.2.2)
39
ERROR 404
Y CURRENT
Y-motor current
(Over current error of Y-motor is detected.)
40
ERROR 423
TAKE-UP TENSION-BAR
Take-up tension bar error
(Origin of tension bar can not be detected)
(Angle change of tension bar can not be
detected)
It occurs under conditions of follows;
・
When initializing operation of the tension
bar fails after detecting the media.
・
When initializing operation of the tension
bar during printing (only without torque
limiter).
・
When retry operation fails two times after
abnormal control of the tension bar (only
without torque limiter).
Tension bar control is not performed after
error outbreak.
→
In case that torque limiter is available,
control the take-up unit.
→
In case that torque limiter is not
available, take up operation is not
performed.
1. Check the setting status of the media.
2. Execute and confirm [#TEST][SENSOR][TAKE-UP
TENSION-BAR].(Confirm that the ON/OFF display
is switched by moving the tension bar up and down.)
3. Check the connector connection of Take-up tension
bar origin sensor and cable.
4. Replace the Take-up tension bar origin sensor.
41
ERROR 425
Take-up WRONG
An error occurred in the take-up status of
the take-up unit.
(A tension bar deviated from the lowest
control position for a certain time.)
When the lower limit of control range
exceeds for a certain time, the error occurs.
The operations after the error outbreak are
as follows.
→
In case that torque limiter is available,
control the take-up unit.
→
In case that torque limiter is not
available, slow acceleration and retry
(twice).
1. Check the setting status of the media.
2. Confirm that tension bar is lowered by taking up the media
with manual SW. (If it is not lowered, adjust the weights.)
3. Execute and confirm [#TEST][SENSOR][TAKE-UP
SLIT-A], [TAKE-UP SLIT-B].(Confirm that the ON/
OFF display is switched by moving the tension bar up
and down.)
4. Check the connector connection of Take-up tension
bar origin sensor and cable.
5. Replace the Take-up tension bar origin sensor.
List of Error Messages (3/7)
No.
LCD
Cause
List of Countermeasures
R.1.0
MAINTENANCE MANUAL > Troubleshooting > Details on Errors and Malfunctions > List of Error Messages
Model
JV300-130/160
Issued 2014.05.30 Revised
F/W ver.
1.10
Remark
1.0
Rev.
Summary of Contents for JV300-130 A