3.3.1 Replacement of the EPL2 Main PCB Assy
List of replacement procedures
Item
Work operation
Description
Ref.
Advance
preparation
1.
Parameter upload
Before the printed-circuit board is replaced, upload its
parameter to the PC.
Covers
2.
Removal of covers, etc.
Remove the Electrical box cover.
6.1.1
EPL2 Main
PCB Assy
3.
Removal of the EPL2 main PCB
assy.
Remove the EPL2 main PCB assy.
6.4.1
4.
Mounting of the EPL2 main PCB
assy.
Mount the EPL2 main PCB assy.
Check
5.
Parameter download
Download the parameters which were uploaded in operation
“1”.
Covers
6.
Mounting of the covers.
Mount the covers that have been removed.
6.1.1
Turn the main power OFF when turning the power OFF.